{"product_id":"sensor-switch-fixture-mount-pir-occupancy-sensor","title":"Sensor Switch Fixture-Mount PIR Occupancy Sensor","description":"\u003cp\u003e\u003cstrong\u003eThe SensorSwitch LSXR is a compact, line-voltage fixture-mount PIR occupancy sensor that automates commercial ceiling lighting with selectable high- or low-mount 360° coverage.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDesigned for warehouses, corridors, offices, and gymnasiums, the LSXR delivers reliable passive infrared motion control at the fixture level. It mounts through a standard 1\/2\" knockout and works on MVOLT 120–277V systems, letting you replace or retrofit fixtures with an on-board motion sensor that reduces unnecessary run time and simplifies compliance with energy codes.\u003c\/p\u003e\n\n\u003ch3\u003eHow does the LSXR detect people and where will it reach?\u003c\/h3\u003e\n\u003cp\u003eThe LSXR uses a passive infrared (PIR) detector to sense large motion such as walking and turns lights on when occupancy is detected. Two interchangeable 360° lenses let you optimize coverage for ceiling height and room layout, so the sensor can be tuned to the installation environment.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-mount lens: 360° coverage up to approximately 45 ft for tall ceilings\u003c\/li\u003e\n  \u003cli\u003eLow-mount lens: 360° coverage for 7–15 ft mounting heights\u003c\/li\u003e\n  \u003cli\u003eBoth lenses focus on large-motion detection—ideal for walking traffic in commercial spaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat installation steps and wiring options are required?\u003c\/h3\u003e\n\u003cp\u003eInstallation is designed to be fast and fixture-friendly: the sensor installs through a 1\/2\" knockout using a threaded chase nipple and secures with a snap-lock bracket that drops the lens 3\" for clearance. Reversible hot\/load wiring reduces wiring confusion and the compact housing fits tight fixture cavities.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMounts through 1\/2\" knockout with threaded chase nipple\u003c\/li\u003e\n  \u003cli\u003eSnap-lock bracket drops lens 3\" for fixture clearance\u003c\/li\u003e\n  \u003cli\u003eReversible hot\/load wires simplify wiring during retrofit or new installs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow do I configure time delay, sensitivity, and testing?\u003c\/h3\u003e\n\u003cp\u003eProgramming is digital and push-button based—no field PIR sensitivity calibration is required. Use the green LED and push buttons to set time delay (30 seconds to 30 minutes), apply a Sunlight Discount Factor, and enter Test Mode to verify coverage quickly during setup.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDigital push-button programming with visible green LED indicator\u003c\/li\u003e\n  \u003cli\u003eTime delay adjustable from 30 seconds up to 30 minutes (default 10 minutes)\u003c\/li\u003e\n  \u003cli\u003eTest Mode for quick commissioning and confirmation of coverage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat certifications and physical specs should I expect?\u003c\/h3\u003e\n\u003cp\u003eThe LSXR is compact and compliant with common commercial requirements: it measures 3.75\"H × 2.50\"W × 4.00\"D, supports MVOLT 120–277 VAC, and is UL\/cUL listed and Title 24 compliant. SensorSwitch backs the product with a five-year limited warranty for commercial installations.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eCompact footprint fits tight fixture spaces (3.75\" × 2.50\" × 4.00\")\u003c\/li\u003e\n  \u003cli\u003eElectrical: MVOLT 120–277 VAC; green LED status indicator\u003c\/li\u003e\n  \u003cli\u003eSafety\/standards: UL\/cUL listed, Title 24 compliant, five-year limited warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWho is this for: The SensorSwitch LSXR is intended for electrical contractors, facility managers, and building owners who need a dependable, code-friendly fixture-mounted occupancy sensor for commercial indoor lighting. It’s especially useful when you want a compact, easy-to-install PIR solution with selectable coverage for different ceiling heights, simple push-button programming for rapid commissioning, and compatibility with MVOLT fixtures in warehouses, corridors, offices, and gym spaces.\u003c\/p\u003e\n\u003csection class=\"product-faq-snippet\"\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Does the LSXR work on 120–277V systems?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: Yes. The LSXR supports MVOLT operation across 120–277 VAC for common commercial fixtures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Can I change detection range for high and low ceilings?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: Yes. Interchangeable high-mount and low-mount 360° lenses optimize coverage for different ceiling heights.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e","brand":"Sensor Switch","offers":[{"title":"Default Title","offer_id":48413426024605,"sku":"B00VX5LJR4","price":53.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/9596\/1757\/files\/sensorswitch-lsxr-front-view.jpg?v=1781264992","url":"https:\/\/nexoltic.com\/products\/sensor-switch-fixture-mount-pir-occupancy-sensor","provider":"Nexoltic","version":"1.0","type":"link"}